Accurate Technology ProScale Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Přijímač Accurate Technology ProScale. Accurate Technology ProScale Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Basic, General Purpose &
Panel Mounted LCD Digital Readouts
ProScale
®
LCD Digital Readouts
OPERATION
Zobrazit stránku 0
1 2 3 4 5 6 ... 47 48

Shrnutí obsahu

Strany 1 - ProScale

Basic, General Purpose & Panel Mounted LCD Digital Readouts ProScale® LCD Digital Readouts OPERATION

Strany 2 - WARRANTY

Operation Manual for LCD Digital Readouts Page 10 of 48 Digital Readout Replacement Chart Digital Readout Type Old Number Replacement General

Strany 3 - Table of Contents

Manual Part # 800-1402-001 Rev E Page 11 of 48 SECTION 2 SET-UP Mounting the Digital Readout General Purpose & Basic DRO The SURFACE MOU

Strany 4 - Page 4 of 48

Operation Manual for LCD Digital Readouts Page 12 of 48 24VDC Operation The General Purpose and the Panel Mounted LCD Digital Readouts will operate

Strany 5 - FCC NOTICE

Manual Part # 800-1402-001 Rev E Page 13 of 48 The LCD The above figure illustrates all the segments available on the LCD Pressing and holding th

Strany 6 - GENERAL INFORMATION

Operation Manual for LCD Digital Readouts Page 14 of 48 SECTION 3 OPERATION Fundamental Operation The following operations & functions app

Strany 7 - About This Manual

Manual Part # 800-1402-001 Rev E Page 15 of 48 Key Functions for standard operation ON/OFF KEY Momentarily press the ON/OFF key to turn D

Strany 8 - Page 8 of 48

Operation Manual for LCD Digital Readouts Page 16 of 48 PLUS (+) & MINUS (–) KEYS Momentarily depressing the + or – key increments or

Strany 9 - Page 9 of 48

Manual Part # 800-1402-001 Rev E Page 17 of 48 Basic Functions MEASUREMENT READING DIRECTION Once the system has been put into operation,

Strany 10 - Page 10 of 48

Operation Manual for LCD Digital Readouts Page 18 of 48 DISPLAYED MEASUREMENT UNITS The measurement units displayed on the Readout when the

Strany 11 - SET-UP

Manual Part # 800-1402-001 Rev E Page 19 of 48 SEGMENT OFFSET ADJUSTMENT This function applies to ProScale Model 150 & Model 250 systems and all

Strany 12 - Panel Mount DRO

Operation Manual for LCD Digital Readouts Page 2 of 48 WARRANTY Accurate Technology, Inc., warrants the ProScale® Digital Measuring Systems against

Strany 13 - The LCD

Operation Manual for LCD Digital Readouts Page 20 of 48 Advanced Functions The following additional functions & operations are available on Gen

Strany 14 - OPERATION

Manual Part # 800-1402-001 Rev E Page 21 of 48 SEND The Digital Readout has an output port that can be used to send measurement information to a

Strany 15 - Page 15 of 48

Operation Manual for LCD Digital Readouts Page 22 of 48 24VDC Input Input / Output Pin Common When the number 3333 is displayed in the upper left c

Strany 16 - (+) & MINUS (–) KEYS

Manual Part # 800-1402-001 Rev E Page 23 of 48 EXTERNAL KEYPAD INPUT The multi-purpose connector on the General Purpose (GP) DRO and the circuit boa

Strany 17 - Basic Functions

Operation Manual for LCD Digital Readouts Page 24 of 48 SPECIAL FUNCTIONS See PROGRAMMING PARAMETERS (Pr24, 25, 26) Special Function Mode allows th

Strany 18 - Page 18 of 48

Manual Part # 800-1402-001 Rev E Page 25 of 48 Hold: F4 The Digital Readout provides a feature that allows the displayed position to be “frozen” i

Strany 19 - /LOWER LIMITS

Operation Manual for LCD Digital Readouts Page 26 of 48 SPECIAL FUNCTION 2: GO/NOGO PROGRAMMING PARAMETER Pr24 set to 2 In certain applications (p

Strany 20 - ROGRAMMING PARAMETER (Pr23)

Manual Part # 800-1402-001 Rev E Page 27 of 48 SPECIAL FUNCTION 3: ACCUMULATOR PROGRAMMING PARAMETER Pr24 set to 3 The Measurement Accumulator Spe

Strany 21 - adders

Operation Manual for LCD Digital Readouts Page 28 of 48 4. View Accumulated Total. To view the accumulated total, press the F4 key. The following

Strany 22 - ROGRAMMING PARAMETER (Pr37)

Manual Part # 800-1402-001 Rev E Page 29 of 48 SPECIAL FUNCTION 4: STATISTICS PROGRAMMING PARAMETER Pr24 set to 4 The General Purpose Digital Read

Strany 23 - Page 23 of 48

Manual Part # 800-1402-001 Rev E Page 3 of 48 Table of Contents SECTION 1 GENERAL INFORMATION ...

Strany 24 - R26) the LCD

Operation Manual for LCD Digital Readouts Page 30 of 48 c. Press the SEND key to transmit the Maximum Measurement to the SPC port. Press the F4 k

Strany 25 - Page 25 of 48

Manual Part # 800-1402-001 Rev E Page 31 of 48 Compensation Functions NOTE: The following features are available ONLY on General Purpose Digital R

Strany 26 - 2: GO/NOGO

Operation Manual for LCD Digital Readouts Page 32 of 48 NON-LINEAR COMPENSATION This function is used to enhance the basic accuracy of the ProSc

Strany 27 - 3: ACCUMULATOR

Manual Part # 800-1402-001 Rev E Page 33 of 48 3. Turn the Digital Readout off. Press and hold down the DATUM key and the ON/OFF key for approxim

Strany 28 - Page 28 of 48

Operation Manual for LCD Digital Readouts Page 34 of 48 Operating the system in compensated mode. After a successful correction table has been pro

Strany 29 - 4: STATISTICS

Manual Part # 800-1402-001 Rev E Page 35 of 48 Changing the Battery A low battery indicator will appear in the lower left corner of the LCD. Press a

Strany 30 - Page 30 of 48

Operation Manual for LCD Digital Readouts Page 36 of 48 Circuit Board Jumpers JP1 FACTORY USE ONLY JP2 Encoder Technology Voltage Defaul

Strany 31 - Compensation Functions

Manual Part # 800-1402-001 Rev E Page 37 of 48 General Purpose & Basic DRO Circuit Board Panel Mount DRO Circu

Strany 32 - -LINEAR COMPENSATION

Operation Manual for LCD Digital Readouts Page 38 of 48 SECTION 4 PROGRAMMING Several functions of the Digital Readouts are user programmab

Strany 33 - DATUM to zero the Readout

Manual Part # 800-1402-001 Rev E Page 39 of 48 The Digital Readout Programming Parameters are listed below. Values in [ ] are the range of values

Strany 34 - Page 34 of 48

Operation Manual for LCD Digital Readouts Page 4 of 48 CHANGING THE BATTERY...

Strany 35 - Changing the Battery

Operation Manual for LCD Digital Readouts Page 40 of 48 Pr 11 – Displayed Measurement Units [0 to 6, 0] This parameter controls the type of mea

Strany 36 - Circuit Board Jumpers

Manual Part # 800-1402-001 Rev E Page 41 of 48 Pr 21 – Backlight Control [0 to 10] (Panel Mount DROs only.) If the Backlight Option is order

Strany 37 - Page 37 of 48

Operation Manual for LCD Digital Readouts Page 42 of 48 Pr 26 – Position Monitor Drift Tolerance. [.0004” to 120”, .01”] This parameter sets the a

Strany 38 - PROGRAMMING

Manual Part # 800-1402-001 Rev E Page 43 of 48 Pr 33 – Offset Addition Preset 3. Range: Any displayable position This value is added to the curren

Strany 39 - Page 39 of 48

Operation Manual for LCD Digital Readouts Page 44 of 48 Pr 37 – Programmable Output Polarity. [0 or 1] Sets the normal state of the programmable

Strany 40 - Page 40 of 48

Manual Part # 800-1402-001 Rev E Page 45 of 48 The following Programming Parameters are available only on General Purpose DROs with firmware ending

Strany 41 - [0 to 16, 0]

Operation Manual for LCD Digital Readouts Page 46 of 48 SECTION 5 MISCELLANEOUS Frequently Asked Questions What does no Encno Encno Encno

Strany 42 - F1 key

Manual Part # 800-1402-001 Rev E Page 47 of 48 SECTION 6 ACCESSORIES ProRF SPC ProRF allows linear measurement or position data to be tr

Strany 43 - [0 to 11, 0]

Operation Manual for LCD Digital Readouts Page 48 of 48 Thank you for choosing a ProScale Product, IT WAS PROUDLY MADE IN THE USA Accurate T

Strany 44 - [0, to 3, 0]

Manual Part # 800-1402-001 Rev E Page 5 of 48 FCC NOTICE This equipment has been tested and found to comply with the limits for a class B digital

Strany 45 - [0 or 1]

Operation Manual for LCD Digital Readouts Page 6 of 48 SECTION 1 GENERAL INFORMATION Introduction ProScale® digital measuring systems are affordabl

Strany 46 - MISCELLANEOUS

Manual Part # 800-1402-001 Rev E Page 7 of 48 About This Manual This manual includes Operating and Programming information for: ProScale Basic, Gen

Strany 47

Operation Manual for LCD Digital Readouts Page 8 of 48 Digital Readout Specifications Linear Measurements: Display Ranges: + 999.999 in; + 399 6

Strany 48 - Page 48 of 48

Manual Part # 800-1402-001 Rev E Page 9 of 48 Digital Readout Feature Matrix This matrix is shown for comparison of features available among the sev

Komentáře k této Příručce

Žádné komentáře